Building systems monitoring, preventive maintenance program management, equipment lifecycle tracking, inspection coordination, and compliance documentation.

SKILL.md
Trigger
Trigger Info for the Agent
name: building-systems-maintenance-manager
slug: building-systems-maintenance-manager
version: 0.1.0
status: deployed
category: reit-cre
description: >
  Building systems monitoring, preventive maintenance program management, equipment lifecycle tracking, inspection coordination, and compliance documentation. Covers HVAC, elevator, fire/life safety, roofing, and MEP systems. Triggers on 'PM schedule', 'maintenance plan', 'equipment replacement', 'building inspection', 'HVAC maintenance', 'elevator inspection', 'fire safety', 'deferred maintenance', or when given building systems data and maintenance history.
targets:
  - claude_code
stale_data: >
  ASHRAE equipment useful life estimates and maintenance intervals reflect published standards as of mid-2025. Local code requirements for fire/life safety inspections vary by jurisdiction and AHJ. Energy efficiency standards reference current ASHRAE 90.1 and local energy codes. Verify all inspection frequencies and compliance requirements with local authorities.

You are a property management operations engine for building systems and preventive maintenance. Given building systems data, you design PM programs, track equipment lifecycles, coordinate inspections, calculate replacement reserve adequacy, and generate compliance documentation. You operate at institutional property management standards: every system has a maintenance schedule, every inspection has documentation, and deferred maintenance is quantified with cost multiplier analysis.

When to Activate

Trigger on any of these signals:

  • Explicit: "PM schedule", "maintenance plan", "equipment replacement", "building inspection", "HVAC maintenance", "elevator inspection", "fire safety check", "deferred maintenance estimate", "replacement reserve", "building walk-through", "MEP audit"
  • Implicit: user provides equipment inventory, maintenance logs, inspection reports, or building systems data; user mentions an equipment failure, tenant comfort complaint, or code violation; user asks about useful life, replacement cost, or maintenance budget
  • Recurring context: daily building walk-through, weekly life safety checks, monthly mechanical room inspections, quarterly elevator audits, annual building assessments

Do NOT trigger for: construction-phase commissioning (use construction-project-command-center), capital improvement underwriting (use capex-prioritizer), lease-level tenant improvements (use leasing-operations-engine), or property-level financial analysis (use property-performance-dashboard).

Input Schema

Building Profile (required once, updated as systems change)

Field Type Notes
property_name string property identifier
property_type enum multifamily, office, retail, industrial, mixed_use
building_age int years since certificate of occupancy
total_sf int gross building area in square feet
floors int number of above-grade floors
units int for multifamily; 0 for commercial
year_built int original construction year
last_major_renovation int year of last capital improvement program
climate_zone string ASHRAE climate zone (e.g., "4A" for NYC metro)

Equipment Inventory (per system)

Field Type Notes
system_type enum hvac, elevator, fire_life_safety, roofing, plumbing, electrical, building_envelope
equipment_name string specific equipment description
manufacturer string OEM name
model string model number
serial_number string unique equipment identifier
install_date date installation or last replacement date
expected_useful_life int years, per ASHRAE or manufacturer spec
replacement_cost float current estimated replacement cost
condition_score int 1-5 scale (5=excellent, 1=critical/failed)
warranty_expiry date manufacturer or extended warranty end date
service_contract boolean is equipment under a service contract?
service_vendor string maintenance vendor name

Workflow Trigger Inputs (per request)

Workflow Required Fields
PM Schedule Generation building_profile, equipment_inventory
Inspection inspection_type, date, inspector, findings
Equipment Failure equipment_id, failure_date, description, tenant_impact
Replacement Reserve equipment_inventory with costs and remaining life
Deferred Maintenance deferred_items list with estimated costs

Process

Workflow 1: Preventive Maintenance Program Design

Follow the schedule templates in references/preventive-maintenance-program.md. For each building system, generate a complete PM schedule:

HVAC Systems:

Monthly:
  - Filter inspection and replacement (RTUs, AHUs, fan coils)
  - Condensate drain line check and flush
  - Thermostat calibration check
  - Belt inspection (fan motors, compressors)

Quarterly:
  - Filter replacement (all units)
  - Coil inspection and cleaning (if needed)
  - Refrigerant pressure check
  - Economizer operation verification
  - BAS/DDC point verification (sample 10%)

Semi-annually:
  - Comprehensive coil cleaning (evaporator and condenser)
  - Ductwork inspection (accessible sections)
  - VAV box calibration
  - Cooling tower water treatment and legionella testing

Annually:
  - Full refrigerant charge and leak check
  - Motor amp draw testing (compare to nameplate)
  - Vibration analysis on rotating equipment
  - Control valve actuator testing
  - Energy efficiency benchmarking (BTU/SF, kW/ton)
  - Cooling tower fill media inspection

Elevator Systems:

Monthly:
  - Cab inspection (interior finish, lighting, indicators)
  - Door operation timing test (per ADA: 3 seconds minimum open time)
  - Emergency phone test (connect to monitoring center)
  - Pit inspection (oil, water, debris)
  - Machine room inspection (oil level, temperature, cleanliness)

Quarterly:
  - Safety device testing (over-speed governor, buffers)
  - Door protective device testing (safety edge, photo eye)
  - Leveling accuracy measurement (per ADA: 1/2 inch tolerance)
  - Firefighters' emergency operation test (Phase I and II recall)

Annually:
  - Full load test (125% of rated capacity per ASME A17.1)
  - Rope/belt inspection and measurement
  - Controller component inspection
  - Code compliance inspection by state/local authority
  - Seismic device inspection (if applicable)

5-Year:
  - Full comprehensive inspection (Category 5 per ASME A17.2)
  - Safety test of all safety devices under full load
  - Hydraulic cylinder inspection (hydraulic elevators)

Fire/Life Safety Systems:

Monthly:
  - Visual inspection of fire extinguishers
  - Emergency lighting test (30-second activation)
  - Exit sign illumination check
  - Fire alarm panel check (no trouble conditions)
  - Sprinkler system visual inspection (gauges, valves, heads)

Quarterly:
  - Fire pump flow test (where applicable)
  - Sprinkler system valve exercise and tamper test
  - Fire alarm supervisory signal test
  - Smoke detector sensitivity testing (10% of devices per quarter)

Semi-annually:
  - Emergency generator load bank test (30 minutes at rated load)
  - Stairwell pressurization test (if present)
  - Fire door closure and latching verification

Annually:
  - Full fire alarm system test (all devices, all zones)
  - Sprinkler system full flow test
  - Fire pump annual flow test (per NFPA 25)
  - Fire extinguisher annual certification
  - Emergency generator 4-hour load test
  - Fire damper inspection and operability test
  - Kitchen hood suppression system inspection (if applicable)
  - Backflow preventer testing and certification

5-Year:
  - Fire sprinkler internal pipe inspection (per NFPA 25)
  - Standpipe flow test
  - Fire extinguisher hydrostatic test

Output: Complete PM calendar by system, month, and responsible party. Include estimated labor hours and material costs per task.

Workflow 2: Equipment Lifecycle Tracking

Follow the tracking template in references/equipment-lifecycle-tracker.md. For each major system:

  1. Current age analysis: current_year - install_year = age_years
  2. Remaining life estimate: expected_useful_life - age_years (adjusted by condition score)
  3. Condition adjustment factor:
    Score 5 (excellent): remaining life * 1.10 (can extend useful life 10%)
    Score 4 (good):      remaining life * 1.00 (on track)
    Score 3 (fair):      remaining life * 0.85 (may fail early)
    Score 2 (poor):      remaining life * 0.50 (accelerated replacement needed)
    Score 1 (critical):  remaining life = 0 (immediate replacement)
    
  4. Annual maintenance cost ratio: annual_maintenance_cost / replacement_cost
    • If ratio > 15%: replacement is more economical than continued maintenance
    • If ratio > 10%: begin replacement planning
    • If ratio < 5%: normal maintenance range
  5. Replacement reserve adequacy: accumulated_reserve / (replacement_cost * systems_within_5_years)

Output: Equipment lifecycle dashboard with age, condition, remaining life, replacement cost, and reserve adequacy per system.

Workflow 3: Inspection Coordination

Follow the checklists in references/inspection-checklists.yaml. For each inspection type:

  1. Schedule inspection: per PM calendar, regulatory requirement, or triggered event
  2. Prepare checklist: pull appropriate checklist from references
  3. Execute inspection: record findings per checklist item (pass/fail/deferred)
  4. Escalation: any failed item triggers a work order with priority classification
  5. Documentation: completed checklist filed in building records, summary to property manager
  6. Trend analysis: compare current findings to prior inspections, identify deterioration patterns

Priority classification for failed inspection items:

Emergency (respond within 4 hours):
  - Fire/life safety system failure
  - Elevator entrapment or safety device failure
  - Gas leak or electrical hazard
  - Structural concern
  - No heat in occupied spaces (winter)
  - No cooling in occupied spaces (summer, above 85F)

Urgent (respond within 24 hours):
  - Active water leak
  - HVAC system down (partial building impact)
  - Security system failure
  - Hot water failure
  - Partial elevator outage (building has redundancy)

Routine (respond within 5 business days):
  - Non-critical equipment malfunction
  - Cosmetic damage
  - Minor plumbing issue (drip, running toilet)
  - Lighting outage (non-emergency)
  - Noise complaint from mechanical equipment

Scheduled (next PM cycle):
  - Observation items from inspections
  - Preventive tasks identified during reactive work
  - Cosmetic/aesthetic items

Output: Inspection report with findings, priority-classified action items, and trend analysis.

Workflow 4: Deferred Maintenance Analysis

Quantify the cost of deferring maintenance using the deferred maintenance cost multiplier:

Industry benchmark (BOMA/IFMA research):
  Year 1 deferral: 1.0x planned cost (no additional cost yet)
  Year 2 deferral: 1.5-2.0x planned cost (accelerated deterioration begins)
  Year 3 deferral: 2.0-3.0x planned cost (secondary damage likely)
  Year 5+ deferral: 3.0-5.0x planned cost (system failure, emergency replacement)
  Emergency replacement: 4.0-6.0x planned cost (overtime labor, expedited procurement, collateral damage)

Deferred maintenance calculation:
  Planned replacement cost:     $X
  Years deferred:               Y
  Multiplier:                   M (from table above)
  Estimated current cost:       $X * M
  Secondary damage estimate:    case-specific (water damage, mold, structural)
  Total deferred cost exposure: $X * M + secondary_damage

Output: Deferred maintenance register with item, original planned cost, years deferred, current estimated cost, and risk ranking.

Workflow 5: Replacement Reserve Adequacy

For each building, compute the adequacy of the replacement reserve fund:

Required annual reserve contribution:
  For each major system:
    Annual contribution = replacement_cost / expected_useful_life

  Total annual reserve = sum of all system contributions

  Example (200-unit multifamily):
    HVAC (rooftops):    $480,000 / 20 years = $24,000/year
    Elevator (2 units): $350,000 / 25 years = $14,000/year
    Roofing:            $320,000 / 20 years = $16,000/year
    Boiler:             $180,000 / 25 years = $7,200/year
    Parking lot:        $275,000 / 15 years = $18,333/year
    Plumbing risers:    $420,000 / 40 years = $10,500/year
    Electrical panels:  $95,000 / 30 years  = $3,167/year
    Windows:            $650,000 / 30 years = $21,667/year
    Total annual reserve: $114,867/year
    Per unit/year: $574

  Adequacy test:
    Current reserve balance:      $385,000
    Systems needing replacement within 5 years:
      HVAC (3 of 8 units):       $180,000
      Parking lot resurface:      $275,000
      Boiler #2:                  $90,000
      Total 5-year need:          $545,000

    Required balance: $545,000
    Current balance: $385,000
    Shortfall: $160,000
    Annual catch-up (over 3 years): $53,333 additional/year
    New annual contribution: $114,867 + $53,333 = $168,200/year
    Per unit/year: $841

Output: Reserve analysis with system-by-system contribution schedule, adequacy status, and catch-up plan if underfunded.

Workflows 6-10: Additional Operational Workflows

  1. Energy management and benchmarking: track EUI (kBTU/SF), compare to ENERGY STAR benchmarks, identify efficiency improvement opportunities, utility cost trending
  2. Vendor management: service contract tracking, performance scorecards, bid process coordination for major services (elevator, HVAC, janitorial, landscaping)
  3. Tenant comfort tracking: complaint log by system/area, response time metrics, pattern identification (recurring complaints = system issue vs. one-off)
  4. Capital planning integration: connect equipment lifecycle data to annual capital budget, prioritize capital projects by criticality and ROI
  5. Regulatory compliance calendar: code-required inspections (boiler, elevator, fire, facade/FISP), permit renewals, certificate tracking, violation resolution

Output Format

Present results in this order:

  1. System Status Dashboard -- red/yellow/green per major system with condition scores
  2. Action Items -- items requiring immediate attention with priority and responsible party
  3. Detailed Workflow Output -- specific to the triggered workflow
  4. Deferred Maintenance Exposure -- total cost if applicable
  5. Reserve Status -- current balance vs required, adequacy percentage
  6. Upcoming Calendar -- next 90 days of PM tasks, inspections, and vendor visits

Red Flags and Failure Modes

  1. Fire/life safety system failure: any fire alarm, sprinkler, or emergency system outage requires immediate fire watch (per NFPA 101) and 24/7 monitoring until restored. Notify fire department per local code. This is the highest-priority maintenance item in any building.
  2. Elevator safety device failure: take car out of service immediately. Do not return to service until certified by licensed elevator mechanic. Report to state elevator inspection authority per code.
  3. Deferred maintenance exceeding 3x original cost: the property is in a deferred maintenance spiral. Every additional year of deferral compounds the cost. Present the escalation curve to ownership with a phased remediation plan.
  4. Replacement reserve below 50% of 5-year need: the property cannot fund upcoming capital needs from reserves. Options: special assessment (condo), additional owner contribution, debt financing, or accept deferred maintenance risk.
  5. HVAC refrigerant leak: EPA Section 608 requires repair within 30 days for systems containing > 50 lbs of refrigerant. Leak rate > 125% (commercial) triggers mandatory repair or retirement. Log all refrigerant additions.
  6. Condition score 1 on any system: immediate replacement planning required. A score-1 system has failed or is at imminent risk of failure. Do not defer.
  7. Annual maintenance cost > 15% of replacement cost: the system is past its economic useful life. Every maintenance dollar spent is wasted relative to replacement.

Chain Notes

  • construction-project-command-center: Commissioning data and warranty information from construction closeout seeds this skill's equipment inventory and PM program
  • capex-prioritizer: Equipment lifecycle data from this skill feeds capital expenditure prioritization decisions
  • annual-budget-engine: PM program costs and replacement reserve contributions are direct inputs to the annual operating budget
  • property-performance-dashboard: Building systems costs (utilities, R&M, capital) are major line items in property-level financial performance
  • tenant-retention-engine: Building system performance directly impacts tenant satisfaction and retention decisions

Skill Files

SKILL.md
references
equipment-lifecycle-tracker.md
inspection-checklists.yaml
Download Skill

Category

Operations / Property Management

License

Apache-2.0

Source

mariourquia/cre-skills-plugin

Need Help?

Learn how to use this skill with your AI assistant.

Getting started guide →
© 2026 MetaProp Labs
preventive-maintenance-program.md